GE Merlin Tankless RO Water System (RO Units)


ge merlin ro unit

This RO Water System is recommended for:

  • kitchens with limited space.

Technical Details and Specifications of the GE Merlin Tankless RO System:

  • This is a fresh GE Merlin - Revision D model.
  • Rejection of Salts and Impurities: Typical TDS Rejection rate is around 90% with new membranes. A standard RO system has a typical TDS rejection rate of around 98.5%. 
  • Install on potable cold water line only.
  • According to GE, this unit should not be connected to a Pressure Tank. 
  • If you wish to use the Merlin to fill an open Atmospheric Storage Tank, you will need a Mechanical Float Valve to turn of the water flow when the water tank gets full.   This works well without the Merlin Booster Pump installed.
  • System requires at least 50 PSI of water pressure to function and turn off properly.  Less than this pressure and the unit may constantly run to drain.
  • Stage 1:  (1) Carbon Block Prefilter, (5 micron),typically lasts 6 months or 5,000 gallons.
  • Stage 2:  (2) RO Elements (working in parallel) - typically lasts 2-4 years
  • Stage 3: (1) Inline Carbon Postfilter  - replace every 6 months
  • Consumer Tips: If you have a lot of particulates in your water, It is recommended that you precede this system with an additional (4.5" x 10") 5 micron Nominal Sediment Filter to give the unit extra protection.
  • For heavy use (>20 gallons purified water per day) GE recommends adding a 4.5"x10" Matrikx CTO/2 Carbon Block Filter preceding the GE Merlin System.  Feedwater intake tubing is 1/2" O.D. 
  • Approximate Dimensions: Depth: 10", Height: 17", Width: 20.5"
  • The optional Booster Pump should only be a GE Merlin Booster Pump.  This is only rated for intermittent Residential Use, not continuous duty commercial use.
  • Notice: Consult your plumber or refrigerator manufacturer about connecting an RO system to your specific refrigerator model.  If and when a booster pump is necessary, only use a Variable Speed Pump, and find out if you should use one that's regulated at 40 PSI or 60 PSI.
  • You can also use this RO system to fill any size Atmospheric Storage Tank (zero pressure - open air) 24 hours a day (720 Gals./ day @77°).  If you wish to use the Merlin to fill an open Atmospheric Storage Tank, you will need a Mechanical Float Valve to turn of the water flow when the water tank gets full.   This works well without the Merlin Booster Pump installed.  
  • Maximum Flow Rate is 1/2 GPM at 50 PSI (with 77° F. water) under normal conditions.
  • Flow Rate is slower for colder water.  For 50 degree cold water you will need 70 PSI pressure to get this same 1/2 GPM flow rate, or just accept a slower flow rate.
  • Feedwater intake tubing is 1/2" O.D. 
  • Typical RO water recovery: 23.7% product water (purified water), and 76.3% waste water at 50 PSI and 77° F.
  • We recommend professional installation for all RO systems for best results
  • GE Merlin Tech Support and Questions: 262-238-4400